Banner
Home >> Products >> PU24
Product name:
PU24
Product Description:

Multi pure aluminum foils incorporated onto two double 8mm thermo cellular (Fire Retardant) polyethylene bubbles, with inner foil and superior heat ressitance in each bubbles structure, with high performance copper aluminum foil on top side, and silver aluminum foil on bottom side. Added 18 microns aluminum and reinforced net.

Product Thickness:

Total nominal thickness = 16mm.

Distributor:

PolyX Global Pty Ltd.

Address:

Smithfleld, NSW, Australia

Thermal Performance:

PU24 product can achieve several Total R-Values depending on the installation method, cavity depth, cavity design and other building components used in the system. For full details about PU24 R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global Pty Ltd. authorized dealersagents.

Total R-Value Example A:
Roof structurecomponents:

  • Outside air film (temperature 36°C)
  • Commercial Metal Roof (1° to 5° slope)
  • Sealed 30mm reflective airspace
  • PU24 Reflective Insulation
  • Unventilated 900mm reflective airspace
  • Suspended 13mm plaster or gypsum board ceiling
  • Indoor air film (temperature 24°C)

Total R-Value = Rt 4.56m2xK/w (heat flow down) Calculation ref: JMF 334r0.32

Total R-Value Example B:
Roof structurecomponents:

  • Outside air film (temperature 12°C)
  • Commercial Metal Roof (1° to 5° slope)
  • Sealed 30mm reflective airspace
  • PU24 Reflective Insulation
  • Unventilated 900mm reflective airspace
  • Suspended 13mm plaster or gypsum board ceiling
  • Indoor air film (temperature 18°C)

Total R-Value = Rt 1.61m2xK/w (heat flow up) Calculation ref: JMF 334r0.32

 

For full details about PU24 R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global Pty Ltd. authorized dealersagents.

To be able to accomplish a specific R Value provided by PolyX Global application guide and or building system, please follow PolyX Global a pplication’s installation guide as demonstrated in PolyX Global applic at ion guide book.

The information in this performance summary data sheet is believed to be true at the time of publication. Polyn X Global Pty Ltd., reserves the right to change specification without notice, and have no obligation or liability for persons misrepresenting or misusing this information in any manner whatsoever. It is clear that the total R-Value depends on the installation and environmental conditions. All values shown are total R- Values for the building applicationsystem and have been calculated using Reflect 3 computer software validated by James M Fricker MIE Aust MAIRAH CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002/Amdt.1 2006. Kindly refer to the PolyX Global technical guide for further information.

PU24 is safe and easy to handle, no protective clothing, gloves or mask is neither needed nor required for the installation or handling of the product. It is the installer duty and responsibility to observe and fulfill with the relevant Occupation Health and Safety requirements for the handling and installation process. Kindly contact PolyX Global authorized agent or distributor for MSDS (Material Safety Data Sheet).

PU24 adds to a Total R-Value (system R value). The effective R value in a system depends on the installation and environmental conditions. The R-Value may be affected or reduced due to dust on upward facing surfaces or as a result of ventilation.

PU24 complies with AS/NZS 4859.1:2002/Amdt.1. Thermal resistance measurement (Material R for group 5 product): 0.413 m2 K/W. Reflective performances of PU24 (tested to ASTM E 408): Aluminum silver side = 97%, Copper antiglare side = 95% reflection of radiant heat.

×