A combination of bubbles and foam PM30™ Multi provides a Thermal break foam in between

Unit 12/49 – 63 Victoria St Smithfield NSW 2164
A core of thermal break fire retardant XPE foam covered by thermo cellular flame retardant double bubbles and topped with high performances low emissivity copper antiglare. A pure aluminum foil on bottom. Added: 18 microns thick aluminum foil with reinforced net.
Total nominal thickness = 9mm.
PolyX Global Pty Ltd.
Smithflied, NSW, Australia
PM30 (Multi) is safe and easy to handle, no protective clothing, gloves or mask is neither needed nor required for the installation or handling of the product. It is the installer duty and responsibility to observe and fulfill with the relevant Occupation Health and Safety requirements for the handling and installation process. Kindly contact PolyX Global Pty Ltd.authorized agent or distributor for MSDS (Material Safety Data Sheet).
PM30 (Multi) adds to a Total R-Value (system R value). The effective R value in a system depends on the installation and environmental conditions. The R-Value may be affected or reduced due to dust on upward facing surfaces or as a result of ventilation.
PM30 (Multi) complies with AS/NZS 4859.1:2002/Amdt.1. Thermal resistance measurement (Material R for group 5 product): 0.221m2 K/W. Reflective performances of PM30(tested to ASTM E 408): Aluminum silver side = 97%, Copper antiglare side = 95% reflection of radiant heat.
PM30 (Multi) product can achieve several Total R-Values depending on the installation method, cavity depth, cavity design and other building components used in the system. For full details about PM30 R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global PtyLtd authorized dealersagents.
Total R-Value = Rt 4.37m2xK/w (heat flow down) Calculation ref: JMF 334r0.32
Total R-Value = Rt 1.41 m2xK/w (heat flow up) Calculation ref: JMF 334r0.32
For full details about PPM30 (Multi) R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global Pty Ltd authorized dealersagents.
Thickness (nominal) | mm | 9 to 12 |
Bubbles Diameter | mm | 9/10 |
Emittance (ASTM) | % | 3 to 5 |
Reflectivity (ASTM) | % | 95 to 97 |
Foil thickness | μ | 7 to 18 |
Foil Purity | % | >99 |
Weight (nominal) | gsm/m² | 430 |
Standard Roll Size | m X m | 1.35m X 22.23m |
Effective Coverage | m² | 30 |
Standard Roll Weight (Gross) | kg | 12.90 |
Roll Diameter | mm | 550 to 730 |
Fire Retardant | – | Yes |
Reinforced Net | – | Yes |
Heavy Duty Formulated | – | Optional |
Anti-Corrosion Coating | – | Optional |
Property | PolyX TM PM30 |
---|---|
Water Vapor Transmission (WVTR) | Low |
Dimension Changes | Low |
Product Shrinkage | Low |
Thermal Stability | High |
Wet Lamination Strength | High |
Dry Lamination Strength | High |
Surface Corrosion Development | Low |
Fungus and Bacteria Resistance | High |
Fire Hazard Properties | Low |
Surface Flame Spread | Low |
Mean time to Ignition | Low |
Noise Reduction | High |
Tensile Strength | High |
Puncture Strength | High |
**Optional Reinforced Net |
To be able to accomplish a specific R Value provided by PolyX Global application guide andor building system, please follow PolyX Global application’s installation guide as demonstrated in PolyX Global application guide book.
The information in this performance summary data sheet is believed to be true at the time of publication. PolyX Global PtyLtd., reserves the right to change specification without notice, and have no obligation or liability for persons misrepresenting or misusing this information in any manner whatsoever. It is clear that the total R-Value depends on the installation and environmental conditions. All values shown are total R- Values for the building applicationsystem and have been calculated using Reflect 3 computer software validated by James M Fricker MIE Aust MAIRAH CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002/Amdt.1 2006. Kindly refer to the PolyX Global technical guide for further information.