Banner
Home >> Products >> PM30
Product name:
PM30 (Multi)
Product Description:

A core of thermal break fire retardant XPE foam covered by thermo cellular flame retardant double bubbles and topped with high performances low emissivity copper antiglare. A pure aluminum foil on bottom. Added: 18 microns thick aluminum foil with reinforced net.

Product Thickness:

Total nominal thickness = 9mm.

Distributor:

PolyX Global Pty Ltd.

Address:

Smithflied, NSW, Australia

Safety Instructions:

PM30 (Multi) is safe and easy to handle, no protective clothing, gloves or mask is neither needed nor required for the installation or handling of the product. It is the installer duty and responsibility to observe and fulfill with the relevant Occupation Health and Safety requirements for the handling and installation process. Kindly contact PolyX Global Pty Ltd.authorized agent or distributor for MSDS (Material Safety Data Sheet).

Reflective Insulation:

PM30 (Multi) adds to a Total R-Value (system R value). The effective R value in a system depends on the installation and environmental conditions. The R-Value may be affected or reduced due to dust on upward facing surfaces or as a result of ventilation.

Compliance:

PM30 (Multi) complies with AS/NZS 4859.1:2002/Amdt.1. Thermal resistance measurement (Material R for group 5 product): 0.221m2 K/W. Reflective performances of PM30(tested to ASTM E 408): Aluminum silver side = 97%, Copper antiglare side = 95% reflection of radiant heat.

Thermal Performance:

PM30 (Multi) product can achieve several Total R-Values depending on the installation method, cavity depth, cavity design and other building components used in the system. For full details about PM30 R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global PtyLtd authorized dealersagents.

Total R-Value Example A:
Roof structurecomponents:

  • Outside air film (temperature 36°C)
  • Commercial Metal Roof (1° to 5° slope)
  • Sealed 30mm reflective airspace
  • PM30 (Multi) Reflective Insulation Unventilated
  • 900mm reflective airspace Suspended 13mm
  • plaster or gypsum board ceiling Indoor air film
  • (temperature 24°C)

Total R-Value = Rt 4.37m2xK/w (heat flow down) Calculation ref: JMF 334r0.32

Total R-Value Example B:
Roof structurecomponents:

  • Outside air film (temperature 12°C)
  • Commercial Metal Roof (1° to 5° slope)
  • Sealed 30mm reflective airspace
  • PM30 (Multi) Reflective Insulation
  • Unventilated 900mm reflective airspace
  • Suspended 13mm plaster or gypsum board ceiling
  • Indoor air film (temperature 18°C)

Total R-Value = Rt 1.41 m2xK/w (heat flow up) Calculation ref: JMF 334r0.32

 

For full details about PPM30 (Multi) R-Values and building systems range for roofs, ceilings, walls and floors kindly contact to PolyX Global Pty Ltd authorized dealersagents.

PolyX TM PM30 Specifications:

 

Thickness (nominal)mm9 to 12
Bubbles Diametermm9/10
Emittance (ASTM)%3 to 5
Reflectivity (ASTM)%95 to 97
Foil thicknessμ7 to 18
Foil Purity%>99
Weight (nominal)gsm/m²430
Standard Roll Sizem X m1.35m X 22.23m
Effective Coverage30
Standard Roll Weight (Gross)kg12.90
Roll Diametermm550 to 730
Fire RetardantYes
Reinforced NetYes
Heavy Duty FormulatedOptional
Anti-Corrosion CoatingOptional
PropertyPolyX TM PM30
Water Vapor Transmission (WVTR)Low
Dimension ChangesLow
Product ShrinkageLow
Thermal StabilityHigh
Wet Lamination StrengthHigh
Dry Lamination StrengthHigh
Surface Corrosion DevelopmentLow
Fungus and Bacteria ResistanceHigh
Fire Hazard PropertiesLow
Surface Flame SpreadLow
Mean time to IgnitionLow
Noise ReductionHigh
Tensile StrengthHigh
Puncture StrengthHigh
**Optional Reinforced Net

To be able to accomplish a specific R Value provided by PolyX Global application guide andor building system, please follow PolyX Global application’s installation guide as demonstrated in PolyX Global application guide book.

The information in this performance summary data sheet is believed to be true at the time of publication. PolyX Global PtyLtd., reserves the right to change specification without notice, and have no obligation or liability for persons misrepresenting or misusing this information in any manner whatsoever. It is clear that the total R-Value depends on the installation and environmental conditions. All values shown are total R- Values for the building applicationsystem and have been calculated using Reflect 3 computer software validated by James M Fricker MIE Aust MAIRAH CPEng and are based on installed product service in accordance with AS/NZS 4859.1:2002/Amdt.1 2006. Kindly refer to the PolyX Global technical guide for further information.

×